Jump to content

Isobutane

From Wikipedia, the free encyclopedia
Isobutane
Chemical structure of isobutane with all atoms explicitly shown
Chemical structure of isobutane with all atoms explicitly shown
Skeletal formula of isobutane
Skeletal formula of isobutane
Ball and stick model of isobutane
Ball and stick model of isobutane
Spacefill model of isobutane
Spacefill model of isobutane
Names
Preferred IUPAC name
2-Methylpropane[1]
Other names
  • Isobutane
  • R600a
Identifiers
3D model (JSmol)
1730720
ChEBI
ChemSpider
ECHA InfoCard 100.000.780 Edit this at Wikidata
EC Number
  • 200-857-2
E number E943b (glazing agents, ...)
1301
KEGG
RTECS number
  • TZ4300000
UNII
UN number 1969
  • InChI=1S/C4H10/c1-4(2)3/h4H,1-3H3 checkY
    Key: NNPPMTNAJDCUHE-UHFFFAOYSA-N checkY
  • CC(C)C
Properties
C4H10
Molar mass 58.124 g·mol−1
Appearance Colorless gas
Odor Odorless
Density
  • 2.51 kg/m3 (at 15 °C, 100 kPa)
  • 563 kg/m3 (at 15 °C, boiling liquid)
Melting point −159.42 °C (−254.96 °F; 113.73 K)[4]
Boiling point −11.7 °C (10.9 °F; 261.4 K)[4]
48.9 mg⋅L−1 (at 25 °C (77 °F))[2]
Vapor pressure 3.1 atm (310 kPa) (at 21 °C (294 K; 70 °F))[3]
8.6 nmol⋅Pa−1⋅kg−1
Conjugate acid Isobutanium
−51.7·10−6 cm3/mol
Thermochemistry
96.65 J⋅K−1⋅mol−1
−134.8  −133.6 kJ⋅mol−1
−2.86959  −2.86841 MJ⋅mol−1
Hazards
GHS labelling:
GHS02: Flammable
Danger
H220
P210
NFPA 704 (fire diamond)
NFPA 704 four-colored diamondHealth 1: Exposure would cause irritation but only minor residual injury. E.g. turpentineFlammability 4: Will rapidly or completely vaporize at normal atmospheric pressure and temperature, or is readily dispersed in air and will burn readily. Flash point below 23 °C (73 °F). E.g. propaneInstability 0: Normally stable, even under fire exposure conditions, and is not reactive with water. E.g. liquid nitrogenSpecial hazards (white): no code
1
4
0
Flash point −83 °C (−117 °F; 190 K)
460 °C (860 °F; 733 K)
Explosive limits 1.4–8.3%
NIOSH (US health exposure limits):
PEL (Permissible)
None[5]
REL (Recommended)
TWA 800 ppm (1900 mg/m3)[5]
IDLH (Immediate danger)
N.D.[5]
Safety data sheet (SDS) lindeus.com
Related compounds
Related alkane
Isopentane
Supplementary data page
Isobutane (data page)
Except where otherwise noted, data are given for materials in their standard state (at 25 °C [77 °F], 100 kPa).
☒N verify (what is checkY☒N ?)
R600-Isobutane 13.6Kg Cylinder by Starke Hvac

Isobutane, also known as i-butane, 2-methylpropane or methylpropane, is a chemical compound with molecular formula HC(CH3)3. It is an isomer of butane. Isobutane is a colorless, odorless gas. It is the simplest alkane with a tertiary carbon atom. Isobutane is used as a precursor molecule in the petrochemical industry, for example in the synthesis of isooctane.[6]

Production

[edit]

Isobutane is obtained by isomerization of butane.

Isomerization of butane

Uses

[edit]

Isobutane is the principal feedstock in alkylation units of refineries. Using isobutane, gasoline-grade "blendstocks" are generated with high branching for good combustion characteristics. Typical products created with isobutane are 2,4-dimethylpentane and especially 2,2,4-trimethylpentane.[7]

Typical acid-catalyzed route to 2,4-dimethylpentane.

Solvent

[edit]

In the Chevron Phillips slurry process for making high-density polyethylene, isobutane is used as a diluent. As the slurried polyethylene is removed, isobutane is "flashed" off, and condensed, and recycled back into the loop reactor for this purpose.[8]

Precursor to tert-butyl hydroperoxide

[edit]

Isobutane is oxidized to tert-butyl hydroperoxide, which is subsequently reacted with propylene to yield propylene oxide. The tert-butanol that results as a by-product is typically used to make gasoline additives such as methyl tert-butyl ether (MTBE).

Miscellaneous uses

[edit]

Isobutane is also used as a propellant for aerosol spray cans.

Isobutane is used as part of blended fuels, especially common in fuel canisters used for camping.[9]

Refrigerant

[edit]

Isobutane is used as a refrigerant.[10] Use in refrigerators started in 1993 when Greenpeace presented the Greenfreeze project with the former East German company Foron [de].[11][12] In this regard, blends of pure, dry "isobutane" (R-600a) (that is, isobutane mixtures) have negligible ozone depletion potential and very low global warming potential (having a value of 3.3 times the GWP of carbon dioxide) and can serve as a functional replacement for R-12, R-22 (both of these being commonly known by the trademark Freon), R-134a, and other chlorofluorocarbon or hydrofluorocarbon refrigerants in conventional stationary refrigeration and air conditioning systems.

As a refrigerant, isobutane poses a fire and explosion risk in addition to the hazards associated with non-flammable CFC refrigerants. Substitution of this refrigerant for motor vehicle air conditioning systems not originally designed for isobutane is widely prohibited or discouraged.[13][14][15][16][17][18][19]

Vendors and advocates of hydrocarbon refrigerants argue against such bans on the grounds that there have been very few such incidents relative to the number of vehicle air conditioning systems filled with hydrocarbons.[20][21]

A leak of isobutane in the refrigerant system of a fridge initiated the 2024 Valencia residential complex fire in Spain, that claimed 10 lives.[22]

Nomenclature

[edit]

The traditional name isobutane was still retained in the 1993 IUPAC recommendations,[23] but is no longer recommended according to the 2013 recommendations.[1] Since the longest continuous chain in isobutane contains only three carbon atoms, the preferred IUPAC name is 2-methylpropane but the locant (2-) is typically omitted in general nomenclature as redundant; C2 is the only position on a propane chain where a methyl substituent can be located without altering the main chain and forming the constitutional isomer n-butane.

References

[edit]
  1. ^ a b Nomenclature of Organic Chemistry : IUPAC Recommendations and Preferred Names 2013 (Blue Book). Cambridge: The Royal Society of Chemistry. 2014. p. 652. doi:10.1039/9781849733069-FP001. ISBN 978-0-85404-182-4. The names 'isobutane', 'isopentane', and 'neopentane' are no longer recommended.
  2. ^ "Solubility in Water". PubChem. National Center for Biotechnology Information. Retrieved 6 April 2017.
  3. ^ "CDC - NIOSH Pocket Guide to Chemical Hazards - Isobutane". CDC - NIOSH Pocket Guide to Chemical Hazards. CDC. Retrieved 28 December 2018.
  4. ^ a b Record in the GESTIS Substance Database of the Institute for Occupational Safety and Health
  5. ^ a b c NIOSH Pocket Guide to Chemical Hazards. "#0350". National Institute for Occupational Safety and Health (NIOSH).
  6. ^ "Patent Watch, July 31, 2006". Archived from the original on March 11, 2007. Retrieved August 8, 2006.
  7. ^ Bipin V. Vora; Joseph A. Kocal; Paul T. Barger; Robert J. Schmidt; James A. Johnson (2003). "Alkylation". Kirk-Othmer Encyclopedia of Chemical Technology. doi:10.1002/0471238961.0112112508011313.a01.pub2. ISBN 0471238961.
  8. ^ Kenneth S. Whiteley. "Polyethylene". Ullmann's Encyclopedia of Industrial Chemistry. Weinheim: Wiley-VCH. doi:10.1002/14356007.a21_487.pub2. ISBN 978-3527306732.
  9. ^ Rietveld, Will (2005-02-08). "Frequently Asked Questions About Lightweight Canister Stoves and Fuels". Backpacking Light (subscription required). Retrieved 2022-06-03.
  10. ^ "Technical Meeting on HCFC Phase-Out: Overview of Advantages and Disadvantages of Alternatives (Montreal, Canada; European Commission on retrofit refrigerants for stationary applications)" (PDF). April 2008. Archived (PDF) from the original on 2009-08-05. Retrieved 2021-05-21.
  11. ^ "GreenFreeze". Greenpeace. 2010-03-15. Archived from the original on 2010-10-05. Retrieved 2013-01-02.
  12. ^ Wolfgang Lohbeck (June 2004). "Greenfreeze: from a snowball to an industrial avalanche" (PDF). Retrieved 2021-05-21.
  13. ^ "U.S. EPA hydrocarbon-refrigerants FAQ". Epa.gov. Retrieved 2010-10-29.
  14. ^ "Compendium of hydrocarbon-refrigerant policy statements, October 2006" (PDF). Archived from the original (PDF) on 2014-08-08. Retrieved 2014-08-01.
  15. ^ "MACS bulletin: hydrocarbon refrigerant usage in vehicles" (PDF). Archived from the original (PDF) on 2011-01-05. Retrieved 2010-10-29.
  16. ^ "Society of Automotive Engineers hydrocarbon refrigerant bulletin". Sae.org. 2005-04-27. Archived from the original on 2005-05-05. Retrieved 2010-10-29.
  17. ^ "Saskatchewan Labour bulletin on hydrocarbon refrigerants in vehicles". Labour.gov.sk.ca. 2010-06-29. Archived from the original on 2009-07-01. Retrieved 2010-10-29.
  18. ^ VASA on refrigerant legality & advisability Archived January 13, 2009, at the Wayback Machine
  19. ^ "Queensland (Australia) government warning on hydrocarbon refrigerants" (PDF). Energy.qld.gov.au. Archived from the original (PDF) on 2008-12-17. Retrieved 2010-10-29.
  20. ^ "New South Wales (Australia) Parliamentary record, 16 October 1997". Parliament.nsw.gov.au. 1997-10-16. Archived from the original on 1 July 2009. Retrieved 2010-10-29.
  21. ^ "New South Wales (Australia) Parliamentary record, 29 June 2000". Parliament.nsw.gov.au. Archived from the original on 22 May 2005. Retrieved 2010-10-29.
  22. ^ Domínguez, Teresa (3 May 2024). "Una fuga del gas refrigerante de la nevera del piso 86 propició el inicio del incendio de Campanar". Levante-EMV (in European Spanish). Retrieved 15 October 2024.
  23. ^ Panico, R. & Powell, W. H., eds. (1994). A Guide to IUPAC Nomenclature of Organic Compounds 1993. Oxford: Blackwell Science. ISBN 0-632-03488-2. https://www.acdlabs.com/iupac/nomenclature/93/r93_679.htm
[edit]